About 104,000 results
Open links in new tab
  1. Hydrotest - an overview | ScienceDirect Topics

    First, a hydrotest is the opportunity to check the leak tightness of mechanical joints such as flanged joints, threaded connections, and swaged fittings in instrument tubing.

  2. Hydrostatic Testing - an overview | ScienceDirect Topics

    In shallow-water pressure gradients, hydrostatic pressures, and hydrotest locations are well understood and accepted (Mappus and Torstrick, 2007). In deepwater, pipeline commissioning …

  3. Hydrostatic Test - an overview | ScienceDirect Topics

    Apr 11, 2012 · A hydrostatic test is defined as a pressure test in which a pipe or other component is filled with water and pressurized to evaluate its structural integrity, typically above normal …

  4. Hydrostatic test of storage tanks using seawater and corrosion ...

    Apr 1, 2021 · Hydrostatic testing is an important method for the quality control of storage tanks in industry. After the tanks have been manufactured or repaired, a…

  5. HydroTest: A web-based toolbox of evaluation metrics for the ...

    Jul 1, 2007 · This paper has introduced the HydroTest web site—a site which provides a consistent collection of evaluation metrics and example datasets for modellers to use in …

  6. Models for predicting the test medium temperature during …

    Aug 1, 2021 · Whereas, during the hydrotest test it is utmost important to correlate changes in the test pressure to the test medium temperature to discern if a leak exists.

  7. Laboratory investigation of MIC threat due to hydrotest using …

    Mar 1, 2013 · Microbiologically Influenced Corrosion (MIC) is a major threat to integrities of pipelines and storage tanks. Even though MIC during hydrotest itself …

  8. Models for predicting the test medium temperature during …

    Aug 1, 2021 · Whereas, during the hydrotest test it is utmost important to correlate changes in the test pressure to the test medium temperature to discern if a leak exists.

  9. Mitigating microbiologically influenced corrosion of an oilfield ...

    Nov 15, 2020 · In the oil and gas industry, microbiologically influenced corrosion (MIC) is a major threat to hydrotest, a procedure which is required to certify whe…

  10. Blending hydrogen in existing natural gas pipelines: Integrity ...

    Dec 1, 2023 · After a hydrotest, a flaw that survived such a test must grow a much smaller value to become critical in a hydrogen blend vs. natural gas. This effect should be counteracted with …